{"product_id":"0-geb45c9eb","title":"JLSFT R860 V7 Server","description":"\u003cp data-start=\"137\" data-end=\"273\"\u003eHigh-performance JLSFT R860 V7 4U server—dual Xeon CPUs, 24 DDR4 slots, NVMe bays, redundant PSUs. Fast UAE delivery. Order yours today!\u003c\/p\u003e\n\u003chr data-start=\"275\" data-end=\"278\"\u003e\n\u003ch2 data-start=\"280\" data-end=\"293\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"294\" data-end=\"603\"\u003eMeet the JLSFT R860 V7, a 4U powerhouse built for virtualization, AI training, and heavy-duty databases. It delivers dual Intel® Xeon® Scalable performance, up to 3 TB DDR4 ECC memory, and flexible NVMe\/SAS\/SATA storage. Its redundant design and optimized cooling keep your critical workloads running nonstop.\u003c\/p\u003e\n\u003chr data-start=\"605\" data-end=\"608\"\u003e\n\u003ch2 data-start=\"610\" data-end=\"634\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"635\" data-end=\"1173\"\u003eThe R860 V7 blends raw compute muscle with enterprise reliability. Equipped with two Intel® Xeon® Scalable processors and 24 DDR4 ECC DIMM slots, it handles memory-intensive tasks with ease. Front-load bays support up to eight NVMe drives or a mix of SAS\/SATA modules for tiered storage. Dual Platinum-rated hot-swap PSUs and tool-free fans ensure 24\/7 uptime. Integrated IPMI and Redfish let you monitor system health, deploy firmware updates, and configure alerts remotely. Ideal for VDI farms, in-memory analytics, and AI\/ML workloads.\u003c\/p\u003e\n\u003chr data-start=\"1175\" data-end=\"1178\"\u003e\n\u003ch2 data-start=\"1180\" data-end=\"1197\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1198\" data-end=\"1484\"\u003e\n\u003cli data-start=\"1198\" data-end=\"1240\"\u003e\n\u003cp data-start=\"1200\" data-end=\"1240\"\u003eDual Intel® Xeon® Scalable CPU sockets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1241\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1243\" data-end=\"1282\"\u003e24 × DDR4 ECC DIMM slots (up to 3 TB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1283\" data-end=\"1329\"\u003e\n\u003cp data-start=\"1285\" data-end=\"1329\"\u003e8 × front-load NVMe\/SAS\/SATA hot-swap bays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1330\" data-end=\"1369\"\u003e\n\u003cp data-start=\"1332\" data-end=\"1369\"\u003eRedundant dual 1600 W Platinum PSUs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1370\" data-end=\"1405\"\u003e\n\u003cp data-start=\"1372\" data-end=\"1405\"\u003eTool-free hot-swap cooling fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1408\" data-end=\"1442\"\u003eIPMI \u0026amp; Redfish remote management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1443\" data-end=\"1484\"\u003e\n\u003cp data-start=\"1445\" data-end=\"1484\"\u003eModular backplane for quick servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1486\" data-end=\"1489\"\u003e\n\u003ch2 data-start=\"1491\" data-end=\"1510\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1511\" data-end=\"1837\"\u003e\n\u003cli data-start=\"1511\" data-end=\"1547\"\u003e\n\u003cp data-start=\"1513\" data-end=\"1547\"\u003e\u003cstrong data-start=\"1513\" data-end=\"1529\"\u003eForm Factor:\u003c\/strong\u003e 4U rack chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1548\" data-end=\"1606\"\u003e\n\u003cp data-start=\"1550\" data-end=\"1606\"\u003e\u003cstrong data-start=\"1550\" data-end=\"1559\"\u003eCPUs:\u003c\/strong\u003e 2 × Intel® Xeon® Scalable (up to 205 W each)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1653\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1653\"\u003e\u003cstrong data-start=\"1609\" data-end=\"1620\"\u003eMemory:\u003c\/strong\u003e 24 × DDR4 ECC DIMM, up to 3 TB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1707\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1707\"\u003e\u003cstrong data-start=\"1656\" data-end=\"1673\"\u003eStorage Bays:\u003c\/strong\u003e 8 × 2.5″ hot-swap NVMe\/SAS\/SATA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1708\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1710\" data-end=\"1745\"\u003e\u003cstrong data-start=\"1710\" data-end=\"1722\"\u003eNetwork:\u003c\/strong\u003e 4 × 10 GbE LOM ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1746\" data-end=\"1797\"\u003e\n\u003cp data-start=\"1748\" data-end=\"1797\"\u003e\u003cstrong data-start=\"1748\" data-end=\"1758\"\u003ePower:\u003c\/strong\u003e 2 × 1600 W Platinum PSUs (redundant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1837\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1837\"\u003e\u003cstrong data-start=\"1800\" data-end=\"1815\"\u003eManagement:\u003c\/strong\u003e IPMI, Redfish, SNMP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1839\" data-end=\"1842\"\u003e\n\u003ch2 data-start=\"1844\" data-end=\"1889\"\u003eSupported OS \/ Applications \/ Industries\u003c\/h2\u003e\n\u003cul data-start=\"1890\" data-end=\"2068\"\u003e\n\u003cli data-start=\"1890\" data-end=\"1943\"\u003e\n\u003cp data-start=\"1892\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1892\" data-end=\"1899\"\u003eOS:\u003c\/strong\u003e VMware ESXi, Windows Server, RHEL, Ubuntu\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1944\" data-end=\"2011\"\u003e\n\u003cp data-start=\"1946\" data-end=\"2011\"\u003e\u003cstrong data-start=\"1946\" data-end=\"1963\"\u003eApplications:\u003c\/strong\u003e Virtualization, AI\/ML training, Big Data, VDI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2012\" data-end=\"2068\"\u003e\n\u003cp data-start=\"2014\" data-end=\"2068\"\u003e\u003cstrong data-start=\"2014\" data-end=\"2029\"\u003eIndustries:\u003c\/strong\u003e Cloud, Finance, Healthcare, Research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2070\" data-end=\"2073\"\u003e\n\u003ch2 data-start=\"2075\" data-end=\"2104\"\u003eBenefits \u0026amp; Compatibility\u003c\/h2\u003e\n\u003cul data-start=\"2105\" data-end=\"2256\"\u003e\n\u003cli data-start=\"2105\" data-end=\"2145\"\u003e\n\u003cp data-start=\"2107\" data-end=\"2145\"\u003eHigh compute density in a 4U chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2146\" data-end=\"2181\"\u003e\n\u003cp data-start=\"2148\" data-end=\"2181\"\u003eCuts rack-space and power costs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2182\" data-end=\"2218\"\u003e\n\u003cp data-start=\"2184\" data-end=\"2218\"\u003eFits standard 19″ racks and PDUs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2219\" data-end=\"2256\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2256\"\u003eEasy upgrades with modular design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2258\" data-end=\"2261\"\u003e\n\u003ch2 data-start=\"2263\" data-end=\"2282\"\u003ePurpose of Use\u003c\/h2\u003e\n\u003cp data-start=\"2283\" data-end=\"2436\"\u003ePerfect for running virtual desktop pools, container clusters, and AI model training. Scales with your data-center needs while keeping operations smooth.\u003c\/p\u003e\n\u003chr data-start=\"2438\" data-end=\"2441\"\u003e\n\u003ch2 data-start=\"2443\" data-end=\"2458\"\u003eHow to Use\u003c\/h2\u003e\n\u003col data-start=\"2459\" data-end=\"2668\"\u003e\n\u003cli data-start=\"2459\" data-end=\"2500\"\u003e\n\u003cp data-start=\"2462\" data-end=\"2500\"\u003eMount the R860 V7 in a 19″ rack bay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2501\" data-end=\"2539\"\u003e\n\u003cp data-start=\"2504\" data-end=\"2539\"\u003eConnect power and network cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2617\"\u003e\n\u003cp data-start=\"2543\" data-end=\"2617\"\u003eAccess IPMI or Redfish to set BIOS, deploy firmware, and monitor health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2618\" data-end=\"2668\"\u003e\n\u003cp data-start=\"2621\" data-end=\"2668\"\u003eHot-swap drives or PSUs live for zero downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"2670\" data-end=\"2673\"\u003e\n\u003ch2 data-start=\"2675\" data-end=\"2711\"\u003ePackaging \/ Weight \/ Dimensions\u003c\/h2\u003e\n\u003cul data-start=\"2712\" data-end=\"2859\"\u003e\n\u003cli data-start=\"2712\" data-end=\"2762\"\u003e\n\u003cp data-start=\"2714\" data-end=\"2762\"\u003e\u003cstrong data-start=\"2714\" data-end=\"2729\"\u003eDimensions:\u003c\/strong\u003e 483 × 740 × 175 mm (W × D × H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2763\" data-end=\"2800\"\u003e\n\u003cp data-start=\"2765\" data-end=\"2800\"\u003e\u003cstrong data-start=\"2765\" data-end=\"2776\"\u003eWeight:\u003c\/strong\u003e ~40 kg (fully loaded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2801\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2803\" data-end=\"2859\"\u003e\u003cstrong data-start=\"2803\" data-end=\"2817\"\u003ePackaging:\u003c\/strong\u003e Foam-lined crate with quick-start guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2861\" data-end=\"2864\"\u003e\n\u003ch2 data-start=\"2866\" data-end=\"2886\"\u003eWarranty \u0026amp; FAQs\u003c\/h2\u003e\n\u003cul data-start=\"2887\" data-end=\"2937\"\u003e\n\u003cli data-start=\"2887\" data-end=\"2937\"\u003e\n\u003cp data-start=\"2889\" data-end=\"2937\"\u003e\u003cstrong data-start=\"2889\" data-end=\"2902\"\u003eWarranty:\u003c\/strong\u003e 1-Year Limited Hardware Warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2939\" data-end=\"2949\"\u003e\u003cstrong data-start=\"2939\" data-end=\"2947\"\u003eFAQ:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2950\" data-end=\"3157\"\u003e\n\u003cli data-start=\"2950\" data-end=\"3015\"\u003e\n\u003cp data-start=\"2952\" data-end=\"3015\"\u003e\u003cem data-start=\"2952\" data-end=\"2979\"\u003eAre drives hot-swappable?\u003c\/em\u003e Yes, all bays support live swaps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3016\" data-end=\"3086\"\u003e\n\u003cp data-start=\"3018\" data-end=\"3086\"\u003e\u003cem data-start=\"3018\" data-end=\"3044\"\u003eCan I mix NVMe and SATA?\u003c\/em\u003e Yes, the bays accept any supported mix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3087\" data-end=\"3157\"\u003e\n\u003cp data-start=\"3089\" data-end=\"3157\"\u003e\u003cem data-start=\"3089\" data-end=\"3116\"\u003eHow do I update firmware?\u003c\/em\u003e Use the IPMI or Redfish web interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3159\" data-end=\"3162\"\u003e\n\u003ch2 data-start=\"3164\" data-end=\"3215\"\u003ePerformance, Quality, Durability \u0026amp; Reliability\u003c\/h2\u003e\n\u003cp data-start=\"3216\" data-end=\"3394\"\u003eValidated for 24\/7 operation, the R860 V7 uses redundant power, cooling, and network paths to maintain peak performance. Enterprise-grade components ensure long-term reliability.\u003c\/p\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3426\"\u003eBest Price Guarantee\u003c\/h2\u003e\n\u003cp data-start=\"3427\" data-end=\"3499\"\u003eFound a lower UAE price? We’ll match it—shop with confidence at NEOTECH.\u003c\/p\u003e\n\u003chr data-start=\"3501\" data-end=\"3504\"\u003e\n\u003ch2 data-start=\"3506\" data-end=\"3561\"\u003eShop Today \u0026amp; Receive Your Delivery Across the UAE!\u003c\/h2\u003e\n\u003cp data-start=\"3562\" data-end=\"3687\"\u003eOrder now for secure, trackable delivery across all Emirates. We pack and ship on your timeline—let’s get you up and running.\u003c\/p\u003e\n\u003chr data-start=\"3689\" data-end=\"3692\"\u003e\n\u003ch2 data-start=\"3694\" data-end=\"3744\"\u003eRequest for Customer Reviews and Testimonials\u003c\/h2\u003e\n\u003cp data-start=\"3745\" data-end=\"3843\"\u003eDeployed the R860 V7? Drop a quick review to help fellow admins make smart infrastructure choices.\u003c\/p\u003e\n\u003chr data-start=\"3845\" data-end=\"3848\"\u003e\n\u003ch2 data-start=\"3850\" data-end=\"3874\"\u003eAfter Sales Support\u003c\/h2\u003e\n\u003cp data-start=\"3875\" data-end=\"3986\"\u003eOur engineers are on standby for installation help, performance tuning, and troubleshooting via phone or email.\u003c\/p\u003e\n\u003chr data-start=\"3988\" data-end=\"3991\"\u003e\n\u003ch2 data-start=\"3993\" data-end=\"4010\"\u003eGet in Touch\u003c\/h2\u003e\n\u003cp data-start=\"4011\" data-end=\"4117\"\u003eNeed custom configurations or bulk quotes? Contact NEOTECH’s sales team for tailored advice and solutions.\u003c\/p\u003e\n\u003chr data-start=\"4119\" data-end=\"4122\"\u003e\n\u003ch2 data-start=\"4124\" data-end=\"4147\"\u003eStock Availability\u003c\/h2\u003e\n\u003cp data-start=\"4148\" data-end=\"4245\"\u003ePlease confirm stock with our team before ordering to secure your delivery slot and avoid delays.\u003c\/p\u003e\n\u003chr data-start=\"4247\" data-end=\"4250\"\u003e\n\u003ch2 data-start=\"4252\" data-end=\"4267\"\u003eDisclaimer\u003c\/h2\u003e\n\u003cp data-start=\"4268\" data-end=\"4393\"\u003eAll specs and pricing may change without notice. Images are illustrative. Verify details with our sales team before purchase.\u003c\/p\u003e","brand":"NEOTECH","offers":[{"title":"Default Title","offer_id":50870552691008,"sku":null,"price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/0737\/7728\/files\/pixelcut-export-2025-07-08T055715.606.jpg?v=1752292604","url":"https:\/\/neotech.ae\/ar\/products\/0-geb45c9eb","provider":"NEOTECH","version":"1.0","type":"link"}