{"product_id":"0-g272f5f50","title":"Meta Brain NF5266M6 2U Rack Server","description":"\u003cp data-start=\"168\" data-end=\"302\"\u003e2U memory-centric server with dual Intel® Xeon®, 16 DIMM slots, 6× NVMe bays \u0026amp; redundant PSUs. Fast, reliable compute. Shop UAE today.\u003c\/p\u003e\n\u003chr data-start=\"304\" data-end=\"307\"\u003e\n\u003ch2 data-start=\"309\" data-end=\"322\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"323\" data-end=\"617\"\u003eMeet the Meta Brain NF5266M6—a 2U rackmount built for serious memory workloads. It pairs dual 3rd Gen Intel® Xeon® Scalable CPUs with 16 DDR4 ECC DIMM slots (up to 4 TB) and 6 hot-swap NVMe bays. Compact yet powerful, it’s ideal for in-memory databases, virtualization, and real-time analytics.\u003c\/p\u003e\n\u003chr data-start=\"619\" data-end=\"622\"\u003e\n\u003ch2 data-start=\"624\" data-end=\"648\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"649\" data-end=\"1044\"\u003eThe NF5266M6 blends high core count with massive RAM capacity. Two Xeon® Scalable processors (up to 28 cores each) drive heavy tasks, while six front-access NVMe\/SATA bays deliver tiered storage. Redundant 2× 800 W Platinum PSUs and adaptive-speed fans keep uptime locked in. Remote management via IPMI 2.0 and Redfish API lets you update firmware, monitor health, and power-cycle from anywhere.\u003c\/p\u003e\n\u003chr data-start=\"1046\" data-end=\"1049\"\u003e\n\u003ch2 data-start=\"1051\" data-end=\"1068\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1069\" data-end=\"1453\"\u003e\n\u003cli data-start=\"1069\" data-end=\"1129\"\u003e\n\u003cp data-start=\"1071\" data-end=\"1129\"\u003eDual 3rd Gen Intel® Xeon® Scalable CPUs (up to 56 cores)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1130\" data-end=\"1170\"\u003e\n\u003cp data-start=\"1132\" data-end=\"1170\"\u003e16× DDR4 ECC DIMM slots (up to 4 TB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1171\" data-end=\"1211\"\u003e\n\u003cp data-start=\"1173\" data-end=\"1211\"\u003e6× 2.5″ hot-swappable NVMe\/SATA bays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1212\" data-end=\"1258\"\u003e\n\u003cp data-start=\"1214\" data-end=\"1258\"\u003eRedundant 2× 800 W Platinum power supplies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1259\" data-end=\"1312\"\u003e\n\u003cp data-start=\"1261\" data-end=\"1312\"\u003e4× front hot-swap cooling fans with dynamic speed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1364\"\u003e\n\u003cp data-start=\"1315\" data-end=\"1364\"\u003eDual 10 GbE onboard LAN + optional OCP 3.0 slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1365\" data-end=\"1415\"\u003e\n\u003cp data-start=\"1367\" data-end=\"1415\"\u003eIPMI 2.0 \u0026amp; Redfish API for full remote control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1416\" data-end=\"1453\"\u003e\n\u003cp data-start=\"1418\" data-end=\"1453\"\u003eStandard 2U, 19″ rack form factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1455\" data-end=\"1458\"\u003e\n\u003ch2 data-start=\"1460\" data-end=\"1479\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1480\" data-end=\"1869\"\u003e\n\u003cli data-start=\"1480\" data-end=\"1548\"\u003e\n\u003cp data-start=\"1482\" data-end=\"1548\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1497\"\u003eProcessors:\u003c\/strong\u003e 2× Intel® Xeon® Scalable (max 28 cores, 3.6 GHz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1549\" data-end=\"1588\"\u003e\n\u003cp data-start=\"1551\" data-end=\"1588\"\u003e\u003cstrong data-start=\"1551\" data-end=\"1562\"\u003eMemory:\u003c\/strong\u003e 16× DDR4 ECC (max 4 TB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1589\" data-end=\"1637\"\u003e\n\u003cp data-start=\"1591\" data-end=\"1637\"\u003e\u003cstrong data-start=\"1591\" data-end=\"1608\"\u003eStorage Bays:\u003c\/strong\u003e 6× 2.5″ NVMe\/SATA hot-swap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1640\" data-end=\"1685\"\u003e\u003cstrong data-start=\"1640\" data-end=\"1654\"\u003eExpansion:\u003c\/strong\u003e 1× OCP 3.0, 2× PCIe Gen4 ×16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1737\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1737\"\u003e\u003cstrong data-start=\"1688\" data-end=\"1700\"\u003eNetwork:\u003c\/strong\u003e 2× 10 GbE RJ45, optional mezzanine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1738\" data-end=\"1779\"\u003e\n\u003cp data-start=\"1740\" data-end=\"1779\"\u003e\u003cstrong data-start=\"1740\" data-end=\"1749\"\u003ePSUs:\u003c\/strong\u003e 2× 800 W Platinum, hot-swap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1780\" data-end=\"1827\"\u003e\n\u003cp data-start=\"1782\" data-end=\"1827\"\u003e\u003cstrong data-start=\"1782\" data-end=\"1797\"\u003eDimensions:\u003c\/strong\u003e 483 × 88.9 × 700 mm (W×H×D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1828\" data-end=\"1869\"\u003e\n\u003cp data-start=\"1830\" data-end=\"1869\"\u003e\u003cstrong data-start=\"1830\" data-end=\"1845\"\u003eManagement:\u003c\/strong\u003e IPMI 2.0, Redfish API\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1871\" data-end=\"1874\"\u003e\n\u003ch2 data-start=\"1876\" data-end=\"1921\"\u003eSupported OS \/ Applications \/ Industries\u003c\/h2\u003e\n\u003cul data-start=\"1922\" data-end=\"2127\"\u003e\n\u003cli data-start=\"1922\" data-end=\"1975\"\u003e\n\u003cp data-start=\"1924\" data-end=\"1975\"\u003e\u003cstrong data-start=\"1924\" data-end=\"1931\"\u003eOS:\u003c\/strong\u003e Windows Server, Ubuntu, RHEL, VMware ESXi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1976\" data-end=\"2063\"\u003e\n\u003cp data-start=\"1978\" data-end=\"2063\"\u003e\u003cstrong data-start=\"1978\" data-end=\"1987\"\u003eApps:\u003c\/strong\u003e In-memory DBs (SAP HANA, Oracle), VDI, big data analytics, virtualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2064\" data-end=\"2127\"\u003e\n\u003cp data-start=\"2066\" data-end=\"2127\"\u003e\u003cstrong data-start=\"2066\" data-end=\"2081\"\u003eIndustries:\u003c\/strong\u003e Finance, healthcare, cloud, research, telco\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2129\" data-end=\"2132\"\u003e\n\u003ch2 data-start=\"2134\" data-end=\"2163\"\u003eBenefits \u0026amp; Compatibility\u003c\/h2\u003e\n\u003cul data-start=\"2164\" data-end=\"2366\"\u003e\n\u003cli data-start=\"2164\" data-end=\"2211\"\u003e\n\u003cp data-start=\"2166\" data-end=\"2211\"\u003eHuge RAM slashes latency for in-memory apps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2212\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2214\" data-end=\"2245\"\u003eTiered NVMe boosts I\/O speeds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2246\" data-end=\"2283\"\u003e\n\u003cp data-start=\"2248\" data-end=\"2283\"\u003eRedundant design maximizes uptime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2284\" data-end=\"2330\"\u003e\n\u003cp data-start=\"2286\" data-end=\"2330\"\u003eBroad OS certification for smooth rollouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2331\" data-end=\"2366\"\u003e\n\u003cp data-start=\"2333\" data-end=\"2366\"\u003eEnergy-efficient build cuts TCO\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2368\" data-end=\"2371\"\u003e\n\u003ch2 data-start=\"2373\" data-end=\"2392\"\u003ePurpose of Use\u003c\/h2\u003e\n\u003cp data-start=\"2393\" data-end=\"2527\"\u003ePerfect for in-memory databases, large-scale VM hosts, real-time analytics, and any workflow where RAM speed and capacity matter most.\u003c\/p\u003e\n\u003chr data-start=\"2529\" data-end=\"2532\"\u003e\n\u003ch2 data-start=\"2534\" data-end=\"2549\"\u003eHow to Use\u003c\/h2\u003e\n\u003col data-start=\"2550\" data-end=\"2776\"\u003e\n\u003cli data-start=\"2550\" data-end=\"2580\"\u003e\n\u003cp data-start=\"2553\" data-end=\"2580\"\u003eMount into a 19″ 2U rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2581\" data-end=\"2623\"\u003e\n\u003cp data-start=\"2584\" data-end=\"2623\"\u003eInstall CPUs and populate DIMM slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2624\" data-end=\"2670\"\u003e\n\u003cp data-start=\"2627\" data-end=\"2670\"\u003eInsert NVMe drives for OS and data tiers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2671\" data-end=\"2723\"\u003e\n\u003cp data-start=\"2674\" data-end=\"2723\"\u003eBoot via IPMI virtual media to install your OS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2724\" data-end=\"2776\"\u003e\n\u003cp data-start=\"2727\" data-end=\"2776\"\u003eMonitor health, logs, and alerts through Redfish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"2778\" data-end=\"2813\"\u003eFor help, contact our support team.\u003c\/p\u003e\n\u003chr data-start=\"2815\" data-end=\"2818\"\u003e\n\u003ch2 data-start=\"2820\" data-end=\"2855\"\u003ePackaging \/ Weight \/ Dimension\u003c\/h2\u003e\n\u003cul data-start=\"2856\" data-end=\"3056\"\u003e\n\u003cli data-start=\"2856\" data-end=\"2903\"\u003e\n\u003cp data-start=\"2858\" data-end=\"2903\"\u003e\u003cstrong data-start=\"2858\" data-end=\"2873\"\u003eDimensions:\u003c\/strong\u003e 483 × 88.9 × 700 mm (W×H×D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2904\" data-end=\"2939\"\u003e\n\u003cp data-start=\"2906\" data-end=\"2939\"\u003e\u003cstrong data-start=\"2906\" data-end=\"2917\"\u003eWeight:\u003c\/strong\u003e ~27 kg (with rails)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2940\" data-end=\"2997\"\u003e\n\u003cp data-start=\"2942\" data-end=\"2997\"\u003e\u003cstrong data-start=\"2942\" data-end=\"2956\"\u003ePackaging:\u003c\/strong\u003e Anti-static foam and heavy-duty carton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2998\" data-end=\"3056\"\u003e\n\u003cp data-start=\"3000\" data-end=\"3056\"\u003e\u003cstrong data-start=\"3000\" data-end=\"3013\"\u003eIncludes:\u003c\/strong\u003e Power cords, rail kit, quick-start guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3058\" data-end=\"3061\"\u003e\n\u003ch2 data-start=\"3063\" data-end=\"3085\"\u003eWarranty and FAQs\u003c\/h2\u003e\n\u003cul data-start=\"3086\" data-end=\"3469\"\u003e\n\u003cli data-start=\"3086\" data-end=\"3135\"\u003e\n\u003cp data-start=\"3088\" data-end=\"3135\"\u003e\u003cstrong data-start=\"3088\" data-end=\"3101\"\u003eWarranty:\u003c\/strong\u003e 1-year NEOTECH limited warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3136\" data-end=\"3469\"\u003e\n\u003cp data-start=\"3138\" data-end=\"3149\"\u003e\u003cstrong data-start=\"3138\" data-end=\"3147\"\u003eFAQs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3152\" data-end=\"3469\"\u003e\n\u003cli data-start=\"3152\" data-end=\"3231\"\u003e\n\u003cp data-start=\"3154\" data-end=\"3231\"\u003e\u003cstrong data-start=\"3154\" data-end=\"3160\"\u003eQ:\u003c\/strong\u003e How much RAM can I install?\u003cbr data-start=\"3188\" data-end=\"3191\"\u003e\u003cstrong data-start=\"3195\" data-end=\"3201\"\u003eA:\u003c\/strong\u003e Up to 4 TB across 16 slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3234\" data-end=\"3305\"\u003e\n\u003cp data-start=\"3236\" data-end=\"3305\"\u003e\u003cstrong data-start=\"3236\" data-end=\"3242\"\u003eQ:\u003c\/strong\u003e Are NVMe drives supported?\u003cbr data-start=\"3269\" data-end=\"3272\"\u003e\u003cstrong data-start=\"3276\" data-end=\"3282\"\u003eA:\u003c\/strong\u003e Yes—6 hot-swap bays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3308\" data-end=\"3387\"\u003e\n\u003cp data-start=\"3310\" data-end=\"3387\"\u003e\u003cstrong data-start=\"3310\" data-end=\"3316\"\u003eQ:\u003c\/strong\u003e What’s the lead time?\u003cbr data-start=\"3338\" data-end=\"3341\"\u003e\u003cstrong data-start=\"3345\" data-end=\"3351\"\u003eA:\u003c\/strong\u003e Standard builds ship in 3–5 days.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3390\" data-end=\"3469\"\u003e\n\u003cp data-start=\"3392\" data-end=\"3469\"\u003e\u003cstrong data-start=\"3392\" data-end=\"3398\"\u003eQ:\u003c\/strong\u003e Is remote console available?\u003cbr data-start=\"3427\" data-end=\"3430\"\u003e\u003cstrong data-start=\"3434\" data-end=\"3440\"\u003eA:\u003c\/strong\u003e Yes, via IPMI virtual media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3471\" data-end=\"3474\"\u003e\n\u003ch2 data-start=\"3476\" data-end=\"3527\"\u003ePerformance, Quality, Durability \u0026amp; Reliability\u003c\/h2\u003e\n\u003cp data-start=\"3528\" data-end=\"3669\"\u003eEngineered for 24\/7 operation under heavy memory loads. Adaptive fans and enterprise-grade components deliver high MTBF and minimal downtime.\u003c\/p\u003e\n\u003chr data-start=\"3671\" data-end=\"3674\"\u003e\n\u003ch2 data-start=\"3676\" data-end=\"3701\"\u003eBest Price Guarantee\u003c\/h2\u003e\n\u003cp data-start=\"3702\" data-end=\"3821\"\u003eFound a lower price in the UAE? We’ll match it. NEOTECH guarantees the best deal, local support, and next-day delivery.\u003c\/p\u003e\n\u003chr data-start=\"3823\" data-end=\"3826\"\u003e\n\u003ch2 data-start=\"3828\" data-end=\"3883\"\u003eShop Today \u0026amp; Receive Your Delivery Across the UAE!\u003c\/h2\u003e\n\u003cp data-start=\"3884\" data-end=\"4035\"\u003eFast, secure shipping across Dubai, Abu Dhabi, Sharjah, Ajman, and beyond. Get your NF5266M6 server on site quickly with our trusted logistics network.\u003c\/p\u003e\n\u003chr data-start=\"4037\" data-end=\"4040\"\u003e\n\u003ch2 data-start=\"4042\" data-end=\"4092\"\u003eRequest for Customer Reviews and Testimonials\u003c\/h2\u003e\n\u003cp data-start=\"4093\" data-end=\"4189\"\u003eGot hands on the NF5266M6? Share your review to help fellow pros choose the right memory server.\u003c\/p\u003e\n\u003chr data-start=\"4191\" data-end=\"4194\"\u003e\n\u003ch2 data-start=\"4196\" data-end=\"4220\"\u003eAfter Sales Support\u003c\/h2\u003e\n\u003cp data-start=\"4221\" data-end=\"4359\"\u003e24\/7 remote diagnostics, firmware updates, and streamlined RMA services. Our experts ensure your server runs smoothly long after purchase.\u003c\/p\u003e\n\u003chr data-start=\"4361\" data-end=\"4364\"\u003e\n\u003ch2 data-start=\"4366\" data-end=\"4383\"\u003eGet in Touch\u003c\/h2\u003e\n\u003cp data-start=\"4384\" data-end=\"4476\"\u003eFor quotes, stock checks, or custom builds, \u003ca data-start=\"4428\" data-end=\"4454\" class=\"\" rel=\"noopener\" href=\"#\"\u003ereach NEOTECH support\u003c\/a\u003e. We’ve got your back.\u003c\/p\u003e\n\u003chr data-start=\"4478\" data-end=\"4481\"\u003e\n\u003ch2 data-start=\"4483\" data-end=\"4506\"\u003eStock Availability\u003c\/h2\u003e\n\u003cp data-start=\"4507\" data-end=\"4623\"\u003eConfirm live stock before ordering. Standard configs ship immediately; custom setups may require 10–15 working days.\u003c\/p\u003e\n\u003chr data-start=\"4625\" data-end=\"4628\"\u003e\n\u003ch2 data-start=\"4630\" data-end=\"4645\"\u003eDisclaimer\u003c\/h2\u003e\n\u003cp data-start=\"4646\" data-end=\"4843\"\u003eAll info is for reference and may change without notice. Images are illustrative and may differ from the actual product. Verify specs, pricing, and availability with our sales team before purchase.\u003c\/p\u003e","brand":"NEOTECH","offers":[{"title":"Default Title","offer_id":50870537027904,"sku":null,"price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/0737\/7728\/files\/pixelcut-export-2025-07-08T095031.018.jpg?v=1752292070","url":"https:\/\/neotech.ae\/products\/0-g272f5f50","provider":"NEOTECH","version":"1.0","type":"link"}