{"product_id":"suprema-biostation-2-fingerprint-access-control-time-attendance-uae","title":"Suprema BioStation 2 Fingerprint Access Control \u0026 Time Attendance Terminal | NEOTECH® UAE","description":"\u003ch1 class=\"p2\"\u003e\n\u003cb\u003eSuprema BioStation 2 biometric terminal with fingerprint authentication, model-dependent RFID credentials, built-in Wi-Fi, Ethernet, PoE and IP65 protection for professional access-control and time-attendance environments.\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h1\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eProduct Status \u0026amp; Manufacturer Identity\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eProduct Status:\u003c\/b\u003e Discontinued \/ End-of-Life\u003cbr\u003e\u003cb\u003eBrand:\u003c\/b\u003e Suprema\u003cbr\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Suprema Inc.\u003cbr\u003e\u003cb\u003eProduct Family:\u003c\/b\u003e BioStation 2\u003cbr\u003e\u003cb\u003eProduct Type:\u003c\/b\u003e Fingerprint Access Control \u0026amp; Time Attendance Terminal\u003cbr\u003e\u003cb\u003eModels Covered:\u003c\/b\u003e BS2-OEPW \/ BS2-OMPW \/ BS2-OHPW\u003cbr\u003e\u003cb\u003eManufacturer EOL Announcement:\u003c\/b\u003e 9 May 2024\u003cbr\u003e\u003cb\u003eLast Order Date:\u003c\/b\u003e 9 November 2024\u003cbr\u003e\u003cb\u003eManufacturer End of Service:\u003c\/b\u003e 9 November 2027\u003cbr\u003e\u003cb\u003eOfficial Successor:\u003c\/b\u003e BioStation 2a\u003cbr\u003e\u003cb\u003eSuccessor Models:\u003c\/b\u003e BS2A-ODPB \/ BS2A-OAPWB\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe original \u003cb\u003eSuprema BioStation 2\u003c\/b\u003e shown on this page is now a discontinued product family.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eSuprema officially announced the discontinuation of BS2-OEPW, BS2-OMPW and BS2-OHPW and designated the newer \u003cb\u003eBioStation 2a\u003c\/b\u003e platform as their successor.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eFor the HID Prox model \u003cb\u003eBS2-OHPW\u003c\/b\u003e, the manufacturer-designated successor is \u003cb\u003eBS2A-OAPWB\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eDiscontinued status does not mean an existing BioStation 2 should automatically be replaced. Existing installations may continue to require the original model for maintenance, expansion or replacement purposes. Customers should verify their exact existing model, credential technology and BioStar environment before ordering.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eThe \u003cb\u003eSuprema BioStation 2\u003c\/b\u003e is a professional IP fingerprint terminal developed for biometric access control and time-attendance applications.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eIt combines a 500 dpi fingerprint sensor with model-dependent RFID credentials, PIN authentication, network connectivity and access-control interfaces in an IP65-rated enclosure.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eBioStation 2 was designed for deployments requiring substantial user and event capacity, networked management and integration with the Suprema ecosystem.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe product remains relevant to organizations maintaining existing BioStation 2 installations, but customers planning a new deployment should be aware that Suprema has discontinued the BS2-OEPW, BS2-OMPW and BS2-OHPW models and introduced \u003cb\u003eBioStation 2a\u003c\/b\u003e as their official successor.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eProfessional Highlights\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003eSuprema original biometric access terminal\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eFingerprint authentication\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e500 dpi fingerprint sensor\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eModel-dependent RFID credential support\u003c\/li\u003e\n\u003cli class=\"li2\"\u003ePIN credential support\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eUp to 500,000 users under manufacturer-defined conditions\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eUp to 20,000 fingerprint credentials for 1:N matching\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eUp to 500,000 fingerprint credentials for 1:1 matching\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eUp to 500,000 card credentials\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eUp to 500,000 PIN credentials\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eUp to 3,000,000 text logs\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e1.0 GHz processor\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e8 GB Flash memory\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e256 MB RAM\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e2.8-inch colour TFT LCD\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eBuilt-in Wi-Fi\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e10\/100 Mbps Ethernet\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eRS-485\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eOSDP V2 compliant\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eWiegand input\/output\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eUSB 2.0 Host\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eIEEE 802.3af PoE\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eIP65-rated enclosure\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eBioStar ecosystem support\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eManufacturer-declared successor available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eFingerprint Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eBiometric Credential:\u003c\/b\u003e Fingerprint\u003cbr\u003e\u003cb\u003eFingerprint Image Size:\u003c\/b\u003e 272 × 320 pixels\u003cbr\u003e\u003cb\u003eImage Depth:\u003c\/b\u003e 8-bit, 256 grayscale\u003cbr\u003e\u003cb\u003eResolution:\u003c\/b\u003e 500 dpi\u003cbr\u003e\u003cb\u003eFingerprint Templates:\u003c\/b\u003e SUPREMA \/ ISO19794-2 \/ ANSI-378\u003cbr\u003e\u003cb\u003eExtractor \/ Matcher:\u003c\/b\u003e MINEX certified and compliant\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eCapacity\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eMaximum Users:\u003c\/b\u003e Up to 500,000 under manufacturer-defined conditions\u003c\/p\u003e\n\u003ch2 class=\"p2\"\u003e\n\u003cb\u003eMaximum Credentials - 1:N\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003eFingerprint: 20,000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"p2\"\u003e\n\u003cb\u003eMaximum Credentials - 1:1\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003eFingerprint: 500,000\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eCard: 500,000\u003c\/li\u003e\n\u003cli class=\"li2\"\u003ePIN: 500,000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eMaximum Text Logs:\u003c\/b\u003e 3,000,000\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eCapacity should be interpreted according to Suprema's specified credential configuration rather than assuming that every maximum can necessarily be used simultaneously in every deployment.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eBioStation 2 Model \u0026amp; RFID Options\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eBioStation 2 was produced in different credential configurations. The exact model number matters.\u003c\/p\u003e\n\u003ch2 class=\"p2\"\u003e\n\u003cb\u003eBS2-OMPW\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003e13.56 MHz MIFARE\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eMIFARE Plus\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eDESFire\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eDESFire EV1 \/ EV2 \/ EV3\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eFeliCa\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eNFC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"p2\"\u003e\n\u003cb\u003eBS2-OHPW\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003e125 kHz HID Prox\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"p2\"\u003e\n\u003cb\u003eBS2-OEPW\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003e125 kHz EM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003eOther BioStation 2 configurations may exist for particular credential technologies or markets.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eDo not purchase a BioStation 2 solely by its front appearance. \u003cb\u003eCheck the exact model number on the existing device or packaging before ordering.\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eSystem Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eCPU:\u003c\/b\u003e 1.0 GHz\u003cbr\u003e\u003cb\u003eMemory:\u003c\/b\u003e 8 GB Flash + 256 MB RAM\u003cbr\u003e\u003cb\u003eCrypto Chip:\u003c\/b\u003e Supported\u003cbr\u003e\u003cb\u003eDisplay:\u003c\/b\u003e 2.8-inch colour TFT LCD\u003cbr\u003e\u003cb\u003eDisplay Resolution:\u003c\/b\u003e 320 × 240 pixels\u003cbr\u003e\u003cb\u003eLED:\u003c\/b\u003e Multi-colour\u003cbr\u003e\u003cb\u003eSound:\u003c\/b\u003e 16-bit\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eNetwork \u0026amp; Interfaces\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eEthernet:\u003c\/b\u003e 10\/100 Mbps, auto MDI\/MDI-X\u003cbr\u003e\u003cb\u003eWi-Fi:\u003c\/b\u003e Built-in IEEE 802.11 b\/g\u003cbr\u003e\u003cb\u003eRS-485:\u003c\/b\u003e 1 channel, Host or Slave selectable\u003cbr\u003e\u003cb\u003eRS-485 Protocol:\u003c\/b\u003e OSDP V2 compliant\u003cbr\u003e\u003cb\u003eWiegand:\u003c\/b\u003e 1 input \/ 1 output\u003cbr\u003e\u003cb\u003eInputs:\u003c\/b\u003e 2 channels\u003cbr\u003e\u003cb\u003eRelay:\u003c\/b\u003e 1 relay\u003cbr\u003e\u003cb\u003eUSB:\u003c\/b\u003e USB 2.0 Host\u003cbr\u003e\u003cb\u003ePoE:\u003c\/b\u003e IEEE 802.3af compliant\u003cbr\u003e\u003cb\u003eTamper:\u003c\/b\u003e Supported\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe previous page incorrectly described the network connection as \u003cb\u003eGigabit Ethernet\u003c\/b\u003e. Manufacturer documentation specifies \u003cb\u003e10\/100 Mbps Ethernet\u003c\/b\u003e, so we have corrected this information.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003ePower\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eInput Voltage:\u003c\/b\u003e 12 VDC\u003cbr\u003e\u003cb\u003eMaximum Current:\u003c\/b\u003e 0.8 A\u003cbr\u003e\u003cb\u003ePoE:\u003c\/b\u003e IEEE 802.3af supported\u003c\/p\u003e\n\u003cp class=\"p2\"\u003ePower and network requirements should be reviewed as part of the complete installation design.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003ePhysical \u0026amp; Environmental Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eDimensions:\u003c\/b\u003e 142 × 144 × 45 mm bottom \/ 38 mm top\u003cbr\u003e\u003cb\u003eDevice Weight:\u003c\/b\u003e Approximately 440 g\u003cbr\u003e\u003cb\u003eBracket Weight:\u003c\/b\u003e Approximately 130 g including washer and screw\u003cbr\u003e\u003cb\u003eIngress Protection:\u003c\/b\u003e IP65\u003cbr\u003e\u003cb\u003eOperating Temperature:\u003c\/b\u003e -20°C to 50°C\u003cbr\u003e\u003cb\u003eStorage Temperature:\u003c\/b\u003e -40°C to 70°C\u003cbr\u003e\u003cb\u003eOperating Humidity:\u003c\/b\u003e 0% to 80%, non-condensing\u003cbr\u003e\u003cb\u003eStorage Humidity:\u003c\/b\u003e 0% to 90%, non-condensing\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eManufacturer-Listed Certifications \/ Compliance:\u003c\/b\u003e CE, UKCA, KC, FCC, BIS, RoHS, REACH and WEEE\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eIP65 Protection\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eSuprema specifies BioStation 2 with an \u003cb\u003eIP65 ingress-protection rating\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThis makes the device suitable for appropriately designed indoor or outdoor installations within the manufacturer's environmental specifications.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eIP65 should not be interpreted as meaning the unit is waterproof under every condition. Installation location, cabling, mounting, environmental exposure and manufacturer's installation requirements remain important.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eBioStar Integration\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eBioStation 2 is designed for use within Suprema's biometric and access-control ecosystem, including compatible BioStar environments.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eDepending on the deployment, the system can be used for functions such as:\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003eUser enrolment and management\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eCredential administration\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eAccess rights\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eDevice configuration\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eEvent monitoring\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eAttendance-related workflows\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eAccess-control administration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003eFor an existing system, customers should verify the BioStar version, device firmware and overall system compatibility before adding or replacing hardware.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eBioStation 2 may be used in appropriately designed systems for:\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003eCorporate offices\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eCommercial buildings\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eWarehouses\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eEducational facilities\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eStaff entrances\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eRestricted-access areas\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eEmployee access control\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eTime and attendance\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eExisting Suprema system expansion\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eLegacy BioStation 2 replacement requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003ePurpose of Use\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eBioStation 2 authenticates users through supported fingerprint, RFID and PIN credentials and can form part of a networked access-control or attendance environment.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe terminal itself should not be treated as a complete access-control installation.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eDepending on the project, additional door hardware, locks, exit devices, power supplies, controllers, network infrastructure, software configuration and other components may be required.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eImportant Legacy Product Guidance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eBioStation 2 is now a \u003cb\u003elegacy\/discontinued product\u003c\/b\u003e, but that does not make every existing unit obsolete for practical use.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThere are two different purchasing situations:\u003c\/p\u003e\n\u003ch2 class=\"p2\"\u003e\n\u003cb\u003eExisting BioStation 2 Installation\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eAn organization may specifically require the original BioStation 2 because it is maintaining an installed system. In this case, verify the exact existing model and credential technology before sourcing a replacement.\u003c\/p\u003e\n\u003ch2 class=\"p2\"\u003e\n\u003cb\u003eNew Access-Control Project\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eFor a new deployment, customers should normally compare the current \u003cb\u003eBioStation 2a\u003c\/b\u003e platform before choosing remaining legacy BioStation 2 inventory.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe correct decision depends on compatibility, project requirements, software environment, credential technology and lifecycle considerations.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eOfficial Successor Information\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eSuprema announced the discontinuation of the BioStation 2 BS2-OEPW, BS2-OMPW and BS2-OHPW models on \u003cb\u003e9 May 2024\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eManufacturer lifecycle information specifies:\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eLast Order:\u003c\/b\u003e 9 November 2024\u003cbr\u003e\u003cb\u003eEnd of Service:\u003c\/b\u003e 9 November 2027\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eSuprema identifies the following successors:\u003c\/p\u003e\n\u003ch3 class=\"p2\"\u003e\n\u003cb\u003eBS2-OEPW → BS2A-ODPB\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eBS2-OMPW → BS2A-ODPB\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eBS2-OHPW → BS2A-OAPWB\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"p2\"\u003eThe newer platform is \u003cb\u003eSuprema BioStation 2a\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eA successor designation does not automatically mean every existing installation is a plug-and-play migration. Credential technology, wiring, software, firmware, mounting, configuration and other system requirements should be reviewed before replacement.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eBioStation 2 vs BioStation 2a\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eBioStation 2\u003c\/b\u003e is the older generation covered by this page.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eBioStation 2a\u003c\/b\u003e is the newer manufacturer-designated successor platform.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThey should not be combined into one product listing because they are distinct product generations with different hardware capabilities, credential support and lifecycle status.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eCustomers searching specifically for an existing BioStation 2 should therefore still be able to identify the older product clearly, while customers planning a new deployment should be informed that BioStation 2a is now available.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eThings to Verify Before Ordering\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eBefore purchasing a BioStation 2, please confirm:\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003eExact model number\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eWhether the requirement is for an existing installation or new project\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eRequired RFID\/card technology\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eExisting fingerprint database requirements\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eBioStar environment and software version\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eNetwork requirements\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eWi-Fi requirements\u003c\/li\u003e\n\u003cli class=\"li2\"\u003ePoE requirements\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eExisting wiring and access-control architecture\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eDoor hardware requirements\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eRequired accessories\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eInstallation environment\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eQuantity\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eProduct condition\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eCurrent availability\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eRemaining manufacturer service lifecycle\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eWhether migration to BioStation 2a should be considered\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003eIf replacing an existing unit, providing a photograph of the product label and exact model number can help reduce compatibility mistakes.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eBuyer Guidance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eDo not select BioStation 2 simply because another unit looks identical.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eDifferent BioStation 2 variants support different RFID technologies.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eFor customers maintaining an existing system, matching the exact model can be important.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eFor customers designing a new system, compare \u003cb\u003eBioStation 2a\u003c\/b\u003e before committing to discontinued BioStation 2 hardware.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThis provides a clearer balance between immediate compatibility and longer-term product lifecycle.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eWhy NEOTECH® UAE?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eAt NEOTECH®, product information is not treated as something we publish once and forget. \u003cb\u003eWe improve it whenever we discover a clearer, safer, or more useful way to serve the customer.\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThat means reviewing manufacturer information, correcting outdated specifications, identifying product lifecycle status, distinguishing exact model configurations, documenting official successor relationships and updating buyer guidance when better information becomes available.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThis BioStation 2 page is an example of that approach. Rather than presenting a discontinued product as though it were still current, we clearly identify its lifecycle while preserving useful information for customers who genuinely need the older model.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eOur objective is simple: help customers understand \u003cb\u003ewhat they are buying, whether it is right for their requirement, and what should be verified before they pay.\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eLearn First. Decide Second.\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eRequest a Quote or Order in the UAE\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eFor a quotation or availability check, please provide:\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003eProduct: Suprema BioStation 2\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eExact model number, if known\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eRequired quantity\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eExisting credential\/card technology\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eWhether this is a replacement or new installation\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eExisting BioStar environment, where applicable\u003c\/li\u003e\n\u003cli class=\"li2\"\u003eDelivery location within the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003eBecause BioStation 2 is discontinued, availability should always be confirmed before payment.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eDelivery - UAE\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eAvailability of discontinued products can vary.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eWhere confirmed available, order handling is generally approximately 1–2 business days.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eStandard UAE transit is typically approximately 3–5 business days after handling.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eWhere legacy stock requires special sourcing, lead time may extend to approximately 10–15 working days or up to 25 working days depending on supplier availability.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eNo stock or delivery commitment should be assumed until confirmed in the quotation\/order documentation.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eFAQ - Suprema BioStation 2\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Is Suprema BioStation 2 still a current product?\u003c\/b\u003e\u003cbr\u003eA: No. Suprema announced the discontinuation of BS2-OEPW, BS2-OMPW and BS2-OHPW on 9 May 2024.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: When was the last-order date for BioStation 2?\u003c\/b\u003e\u003cbr\u003eA: Suprema lists 9 November 2024 as the last-order date for BS2-OEPW, BS2-OMPW and BS2-OHPW.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: When does manufacturer service end?\u003c\/b\u003e\u003cbr\u003eA: Suprema lists 9 November 2027 as the End of Service date for these discontinued BioStation 2 models.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: What is the official replacement for BioStation 2?\u003c\/b\u003e\u003cbr\u003eA: Suprema designates BioStation 2a as the successor platform. BS2-OEPW and BS2-OMPW map to BS2A-ODPB, while BS2-OHPW maps to BS2A-OAPWB.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Is BioStation 2 the same as BioStation 2a?\u003c\/b\u003e\u003cbr\u003eA: No. They are different product generations. BioStation 2 is the older discontinued family, while BioStation 2a is its newer successor platform.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Does BioStation 2 support fingerprint authentication?\u003c\/b\u003e\u003cbr\u003eA: Yes. Fingerprint is the primary biometric credential supported by BioStation 2.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: What is the fingerprint sensor resolution?\u003c\/b\u003e\u003cbr\u003eA: Suprema specifies 500 dpi.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: How many fingerprint credentials can BioStation 2 store?\u003c\/b\u003e\u003cbr\u003eA: Suprema specifies up to 20,000 fingerprint credentials for 1:N operation and up to 500,000 for 1:1 operation.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: How many event logs can it store?\u003c\/b\u003e\u003cbr\u003eA: Up to 3,000,000 text logs are specified.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Does BioStation 2 support RFID cards?\u003c\/b\u003e\u003cbr\u003eA: Yes, but RFID technology depends on the exact model. For example, BS2-OMPW supports MIFARE-family credentials while BS2-OHPW supports HID Prox.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Does BioStation 2 have Wi-Fi?\u003c\/b\u003e\u003cbr\u003eA: Suprema specifies built-in IEEE 802.11 b\/g Wi-Fi for the relevant BioStation 2 models covered here.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Does it support Gigabit Ethernet?\u003c\/b\u003e\u003cbr\u003eA: No. Manufacturer documentation specifies 10\/100 Mbps Ethernet. The previous NEOTECH® page's Gigabit Ethernet statement has therefore been corrected.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Does BioStation 2 support PoE?\u003c\/b\u003e\u003cbr\u003eA: Yes. Suprema specifies IEEE 802.3af PoE support.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Is BioStation 2 suitable for outdoor installation?\u003c\/b\u003e\u003cbr\u003eA: Suprema specifies an IP65 rating and an operating range of -20°C to 50°C. The complete installation must still follow the manufacturer's environmental and mounting requirements.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: I already use BioStation 2. Should I automatically replace it with BioStation 2a?\u003c\/b\u003e\u003cbr\u003eA: Not necessarily. If the existing system is operating correctly, replacement should be based on lifecycle planning, compatibility and actual requirements rather than simply because a newer generation exists.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Can I still buy BioStation 2?\u003c\/b\u003e\u003cbr\u003eA: Remaining or legacy stock may exist through supply channels, but availability must be checked because the manufacturer has discontinued the relevant models.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eQ: Can NEOTECH® help identify my exact BioStation 2 model?\u003c\/b\u003e\u003cbr\u003eA: Yes. Provide the model number from the device label and, where useful, photographs of the existing unit so the requested configuration can be checked before quotation.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eRelated Products\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eSuprema BioStation 2a BS2A-OAPWB\u003c\/b\u003e - current successor to BioStation 2 BS2-OHPW where applicable.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eOther BioStation 2a configurations should be selected according to the required RFID technology, network connectivity and existing system requirements.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eContact - NEOTECH® UAE\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eFor product identification, quotation, legacy availability or successor-model guidance, contact NEOTECH® UAE and provide the exact BioStation 2 model number where available.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cb\u003eDisclaimer - NEOTECH® UAE\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"p2\"\u003eBioStation 2 is a discontinued Suprema product family. Specifications and lifecycle information should be considered together with the exact model number and the requirements of the existing access-control environment.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eAvailability of discontinued hardware is not guaranteed. Remaining products may differ by model, production period, packaging, firmware or supply source.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eAn official successor designation does not guarantee a direct drop-in replacement for every existing installation. Customers should verify credential technology, software and firmware compatibility, wiring, mounting, accessories, system architecture, availability, product condition, remaining support lifecycle and commercial terms before payment.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eNEOTECH® product supply does not imply installation, commissioning, system integration, project management or ongoing maintenance unless separately agreed in writing.\u003c\/p\u003e\n\u003ch3 class=\"p2\"\u003e\n\u003cb\u003eLast Updated: 6 October 2026 (GST, UTC+4)\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\n\u003c\/h3\u003e","brand":"Suprema","offers":[{"title":"Default Title","offer_id":49727383306560,"sku":null,"price":5818.8,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/0737\/7728\/files\/pixelcut-export-3755.jpg?v=1791285302","url":"https:\/\/neotech.ae\/products\/suprema-biostation-2-fingerprint-access-control-time-attendance-uae","provider":"NEOTECH","version":"1.0","type":"link"}