Generic (OEM)

2.12 × 12 mm FDX-B 134.2kHz Animal Microchip | NEOTECH® UAE

2.12 × 12 mm FDX-B 134.2kHz Animal Microchip | NEOTECH® UAE

(269)
Regular price AED 0.00
Regular price Sale price AED 0.00
Sale Available on Request
Shipping calculated at checkout.
Quantity

Implantable 2.12 × 12 mm bioglass RFID transponder for animal identification, available in ISO 11784 / ISO 11785 FDX-B 134.2kHz configurations for compatible veterinary and livestock identification systems.

Product Type: Implantable Animal Identification Microchip
Form Factor: Glass Transponder
Size: 2.12 × 12 mm
Frequency: 134.2 kHz
Protocol: FDX-B
Standards: ISO 11784 / ISO 11785
Technology: Passive LF RFID
Application: Animal Identification and Traceability

2.12 × 12 mm Animal Identification Microchip in UAE

The 2.12 × 12 mm animal microchip is a small passive LF RFID glass transponder designed for permanent or long-term identification of compatible animals through an electronic identification number.

The commonly available configuration operates at:

134.2 kHz

using:

FDX-B

and is designed around:

ISO 11784 / ISO 11785

animal identification standards. Current animal-ID suppliers list 2.12 × 12 mm as one of the established glass-transponder sizes for pet and livestock identification.

The microchip does not contain GPS, does not actively transmit a location, and does not require an internal battery.

It stores an identification code that can be read when a compatible animal microchip reader is brought within reading range.

Exact Product Identification

Product: Animal Identification Microchip

Type: Implantable Glass RFID Transponder

Size: 2.12 × 12 mm

Operating Frequency: 134.2 kHz

RFID Type: Low Frequency / LF

Protocol: FDX-B

Standards: ISO 11784 / ISO 11785

Power Source: Passive — no battery

Typical Use: Animal identification and traceability

Reader Requirement: Compatible 134.2 kHz FDX-B animal microchip reader

Key Features

  • 2.12 × 12 mm glass transponder format
  • Passive LF RFID technology
  • 134.2 kHz operating frequency
  • FDX-B animal identification protocol
  • ISO 11784 / ISO 11785 compatible configuration
  • No internal battery
  • No routine charging
  • Contactless identification
  • Unique electronic ID capability depending on chip configuration
  • Suitable for compatible pet and livestock identification workflows
  • Can be supplied in sterile implantation configurations depending on selected product
  • Barcode-label options available on some implanter configurations
  • Compatible handheld reader options available separately

2.12 × 12 mm Bioglass Construction

Animal microchips of this type are normally enclosed in a small biocompatible glass capsule.

Current animal-identification product ranges list:

  • 1.25 × 7 mm
  • 1.4 × 8 mm
  • 2.12 × 12 mm

as common implantable glass-transponder sizes.

The 2.12 × 12 mm format is larger than modern mini-microchip formats and should therefore be selected according to:

  • Animal type
  • Veterinary preference
  • Implantation method
  • Applicable identification requirements

ISO 11784 / ISO 11785

For international animal identification, two standards are especially relevant:

ISO 11784

defines the code structure used for radio-frequency animal identification.

ISO 11785

defines technical communication between the animal transponder and compatible reader.

Current 134.2 kHz FDX-B animal-ID transponders are commonly supplied in configurations designed to comply with these standards.

For tenders or regulated programs, documentary evidence of compliance should be requested from the supplier for the exact batch and manufacturer being quoted.

FDX-B 134.2 kHz

FDX-B stands for:

Full Duplex – B

It is one of the widely used LF RFID formats for animal identification.

The operating frequency is:

134.2 kHz

A compatible reader energizes the passive microchip and receives the stored identification number.

Passive RFID — No Battery

The microchip is passive.

This means it contains:

  • No rechargeable battery
  • No disposable battery
  • No SIM card
  • No GPS receiver
  • No active cellular transmitter

The reader supplies the electromagnetic field required for communication.

This is one reason passive RFID microchips can be used for long-term identification applications.

Important: This Is Not a GPS Tracker

A common misunderstanding is that an implanted animal microchip continuously tracks an animal.

It does not.

The microchip provides an electronic identification number when scanned by a compatible reader at close range.

It does not normally provide:

  • Real-time GPS location
  • Mobile-app location tracking
  • Cellular communication
  • Long-range tracking

If active real-time location tracking is required, a separate GPS/cellular animal-tracking device would be needed.

Read Distance

Read distance depends on:

  • Reader antenna
  • Reader power
  • Microchip orientation
  • Implantation position
  • Animal tissue
  • Environmental interference
  • Chip design

Current 2.12 × 12 mm FDX-B references commonly quote short-range reading distances in the approximate 0–10 cm range, depending on the reader and conditions.

NEOTECH® does not recommend promising a fixed read distance without testing the actual chip/reader combination.

Unique Identification Code

Animal-identification microchips are generally supplied with a unique electronic code.

Depending on the selected chip and project, manufacturers may also supply:

  • Printed barcode labels
  • Matching ID stickers
  • Packaging labels
  • Database references
  • ICAR-related numbering options

The exact code structure should be confirmed before bulk procurement.

ICAR Consideration

For formal livestock or recognized animal-identification programs, the customer may require:

  • ICAR manufacturer/product registration
  • Country code allocation
  • Manufacturer code
  • Traceable unique numbers

Not every generic 134.2 kHz chip should automatically be described as ICAR-approved.

If ICAR status is required, NEOTECH® should obtain the supporting documentation for the exact brand, chip and number allocation before quotation.

Sterile Implanter Option

Many animal microchips are available preloaded inside a single-use implantation syringe.

Current market configurations commonly include:

  • Glass transponder
  • Sterile single-use implanter
  • Stainless steel implantation needle
  • Individual sterile pouch
  • Barcode labels

Some suppliers describe EO / ethylene oxide sterilization.

However, the customer inquiry only says:

Animal Microchip — Glass Model T.I.S — Glass Size 2.12 × 12 mm

It does not confirm whether a sterile syringe/implanter is required.

For this inquiry, that must be clarified before final quotation.

Important Inquiry Clarification

For the 2,000-piece Crown Farms requirement, I recommend confirming these points before pricing:

1. Standard

Do they require:

ISO 11784 / ISO 11785 FDX-B?

2. Frequency

Is the required frequency:

134.2 kHz?

3. Supply Format

Do they require:

  • Glass transponder only
  • Preloaded sterile syringe
  • Individual sterile packaging

4. Numbering

Do they require:

  • Factory-programmed unique IDs
  • ICAR-compliant numbering
  • Specific country/manufacturer code
  • Random unique numbering

5. Barcode Labels

How many matching barcode labels are required per chip?

6. Sterilization

Is EO-sterile packaging mandatory?

7. Certification

Do they require:

  • ISO declaration
  • ICAR certificate
  • CE or other supporting documentation
  • Sterilization certificate
  • Batch traceability

8. Application

Is the microchip for:

  • Cattle
  • Sheep/goats
  • Horses
  • Pets
  • Another animal type

This matters because 2.12 × 12 mm may be correct for one program but not necessarily the preferred size for every animal.

Veterinary and Animal Identification Applications

Potential applications include:

  • Veterinary animal identification
  • Pet identification
  • Livestock identification
  • Breeder records
  • Farm animal management
  • Shelter identification
  • Animal traceability
  • Ownership identification
  • Veterinary registration

The microchip itself only supplies the electronic identity.

Registration databases, software and legal records are separate systems.

Cattle and Livestock Applications

The 2.12 × 12 mm format may be considered for certain livestock and farm-animal identification programs.

However, many livestock programs may alternatively use:

  • Ear tags
  • HDX tags
  • FDX-B ear tags
  • Rumen bolus tags

depending on the animal and regulatory requirement.

The customer’s intended identification program should therefore be confirmed.

Pet Identification

The same 134.2 kHz FDX-B technology is also widely associated with companion-animal microchipping.

Modern pet applications often use smaller transponder sizes as well, so 2.12 × 12 mm should not automatically be described as the preferred pet size.

The veterinarian or project specification should determine the size.

Animal Shelters

Potential applications include:

  • Identification
  • Intake records
  • Adoption tracking
  • Ownership records
  • Reunification workflows

The microchip number normally needs to be linked to an appropriate registration database to make the identification useful beyond the reader display.

Breeders

Breeders may use microchip IDs to associate an animal with:

  • Pedigree records
  • Health records
  • Ownership
  • Internal breeding records

Again, the electronic ID alone does not contain these full records; it functions as an identifier linked to another system.

Reader Compatibility

A compatible reader should support:

134.2 kHz

and:

FDX-B / ISO 11784 / ISO 11785

NEOTECH® already has indexed pages for compatible-category animal RFID readers, including a 134.2 kHz Animal RFID Reader and BYX Smart 134.2 kHz RFID Animal Reader, making them logical internal links from this microchip page.

Reader and Microchip Workflow

A typical process is:

Animal

Implanted 134.2 kHz FDX-B Microchip

Compatible Animal Microchip Reader

Unique ID Displayed

ID Checked Against Registration / Farm / Veterinary Database

The reader does not automatically know the owner or animal details unless the ID has been registered in the relevant system.

Things to Verify Before Ordering

Please confirm:

  • Exact size: 2.12 × 12 mm
  • Frequency: 134.2 kHz
  • FDX-B requirement
  • ISO 11784 / ISO 11785 requirement
  • Animal type
  • Glass tag only or sterile injector
  • Needle size
  • Sterilization requirement
  • Unique-ID coding format
  • ICAR requirement
  • Country/manufacturer code requirement
  • Barcode-label quantity
  • Required quantity
  • Reader compatibility
  • Supporting certificates
  • Packaging requirement

For bulk orders such as 2,000 pieces, a written technical specification and sample approval are recommended before production or procurement.

Who Should Consider This Product?

This 2.12 × 12 mm FDX-B microchip may be considered by:

  • Veterinary clinics
  • Farms
  • Livestock operators
  • Breeders
  • Animal shelters
  • Animal-registration organizations
  • Government/municipal animal programs
  • Research and animal-management operations

It should not be selected solely from the physical dimensions.

The required identification standard and approved numbering scheme should be confirmed first.

Why NEOTECH® UAE?

Animal-identification microchips look simple, but several details can materially change whether a product is acceptable.

Before supplying a bulk order, NEOTECH® recommends confirming:

Is the required protocol definitely FDX-B?

Is 134.2 kHz mandatory?

Is ISO 11784/11785 required?

Is ICAR registration required?

Is the chip supplied alone or inside a sterile syringe?

How many barcode labels are required?

What animal is being identified?

Which reader/database will be used?

This prevents purchasing a microchip that is physically the correct size but wrong for the customer’s identification program.

Learn First. Decide Second. Buy Only If It Is Right for Your Needs.

There is absolutely no obligation or pressure to proceed with the purchase with us.

Delivery – UAE

NEOTECH® supplies within the United Arab Emirates only.

Standard Shipping: Free

Order Cut-Off: 14:00 GST

Handling: 1–2 business days for applicable available stock

Standard Transit: 3–5 business days

Estimated Standard Delivery: 4–7 business days for applicable available stock

For bulk, sterile, custom-coded or special-order microchips, lead time may extend to approximately 10–15 working days or up to 25 working days after payment/order confirmation, depending on supplier availability, numbering requirements and production status.

Exact specification, certification, sterile packaging and coding requirements should be agreed before order confirmation.

FAQ - 2.12 × 12 mm FDX-B 134.2kHz Animal Microchip

Q: What is a 2.12 × 12 mm animal microchip?
A: It is a small implantable glass RFID transponder used for electronic animal identification.

Q: What frequency does this type of animal microchip use?
A: A common standardized configuration operates at 134.2 kHz using the FDX-B protocol.

Q: Is it ISO 11784 / ISO 11785 compliant?
A: ISO-compliant versions are widely available, but compliance should be confirmed for the exact manufacturer/product being quoted.

Q: What is FDX-B?
A: FDX-B is a full-duplex LF RFID protocol widely used for animal identification.

Q: Does the microchip have GPS?
A: No. A standard passive animal microchip does not contain GPS.

Q: Can I track the animal in real time?
A: No. The microchip must be scanned at close range using a compatible reader.

Q: Does it need a battery?
A: No. It is passive RFID.

Q: What is the size?
A: Approximately 2.12 mm diameter × 12 mm length.

Q: Is the chip made of glass?
A: Yes, the relevant configuration is an implantable glass/bioglass transponder.

Q: Is it supplied sterile?
A: Sterile preloaded injector versions are available, but this should be confirmed for the exact product ordered.

Q: Is a syringe included?
A: Not necessarily. The quotation must state whether it is the glass transponder only or a preloaded sterile implanter.

Q: Can it include barcode labels?
A: Yes, many suppliers provide matching barcode labels with sterile implantation kits, but the quantity varies by configuration.

Q: Can it be read with a standard RFID reader?
A: It requires an animal-ID reader compatible with 134.2 kHz FDX-B / ISO 11784/11785.

Q: Can NEOTECH® supply the reader as well?
A: NEOTECH® already lists compatible-category 134.2 kHz animal RFID readers that can be reviewed separately.

Q: Is it suitable for cattle?
A: It may be suitable for applicable livestock-identification programs, but the program specification should determine whether an implantable chip, ear tag or rumen bolus is required.

Q: Is it suitable for pets?
A: 134.2 kHz FDX-B is widely used for companion-animal identification, but the preferred transponder size should be confirmed with the veterinarian or project specification.

Q: Is the chip ICAR certified?
A: Do not assume so. ICAR status depends on the exact manufacturer/product and coding arrangement. Supporting documentation should be requested where required.

Q: What information should I provide for a quotation?
A: Please provide quantity, animal type, exact size, frequency, ISO/FDX-B requirement, sterile syringe requirement, ICAR requirement, numbering format and barcode-label requirement.

Related Products

  • 134.2 kHz Animal RFID Reader
  • BYX Smart 134.2 kHz Animal Reader
  • FDX-B Animal Microchip Readers
  • Animal RFID Tags
  • Livestock RFID Identification
  • RFID Ear Tags
  • RFID Rumen Bolus Tags
  • Veterinary Identification Equipment

Helpful Internal Links

  • Animal RFID Readers
  • RFID Animal Identification
  • Veterinary RFID Equipment
  • Livestock Identification
  • RFID Tags
  • Animal Tracking & Identification
  • NEOTECH® Learning Center

Contact - NEOTECH® UAE

For specification review and bulk quotation:

Email: support@neotech.ae

Address: Store 13, Computer Building, Al Fahidi, Bur Dubai, Dubai 44245, UAE

Please provide:

Product: Animal Microchip
Glass Size: 2.12 × 12 mm
Quantity:
Frequency: 134.2 kHz required?
Protocol: FDX-B required?
ISO 11784/11785: Required?
Animal Type:
Sterile Injector Required: Yes / No
ICAR Requirement: Yes / No
Barcode Labels Required:
Reader Model Currently Used:

Disclaimer - NEOTECH® UAE

NEOTECH® is operated by NEOLYN TECHNOLOGY LLC in the UAE.

This page describes a 2.12 × 12 mm implantable animal-identification glass transponder configuration commonly available as 134.2 kHz FDX-B under ISO 11784 / ISO 11785. Current manufacturer and supplier references confirm that 2.12 × 12 mm is a standard available size in this category.

The customer inquiry that prompted this page specifies “Animal Microchip – Glass Model T.I.S – Glass Size 2.12 × 12 mm – Qty 2,000”, but it does not itself specify frequency, protocol, sterilization, ICAR status, numbering scheme or syringe configuration. Those items should therefore be confirmed before a commercial quotation.

“ISO-compatible,” “ICAR-certified,” “sterile,” “biocompatible,” “unique ID,” or similar technical/compliance claims should only be applied to the exact supplied product when supported by manufacturer documentation.

The microchip is an identification transponder, not a GPS tracking device.

Implantation should be performed by an appropriately qualified person and in accordance with applicable veterinary, animal-welfare and local regulatory requirements.

Reader compatibility depends on frequency, protocol, reader antenna and the exact chip configuration.

Images may show a representative microchip or implantation syringe rather than the final supplied brand/configuration.

Last Updated: 19 September 2026 (GST, UTC+4)

View full details